5

E

NERGY

U

SE

(EU)

26

EU 3

C

OMMISSIONING

a) Commissioning planning 2 credits for:

i.

Commissioning plans that detailed all specified commissioning

work for HVAC&R, lighting and where applicable other systems

that impact on energy use and indoor environmental quality;

ii.

The commissioning plan shall be endorsed by an independent

Commissioning Authority

( iCXA )

;

b) Commissioning reports 2 credits for:

i.

Commissioning reports for HVAC&R, lighting and where

applicable other systems that impact on energy use and indoor

environmental quality;

ii.

commissioning reports shall be endorsed by an independent

Commissioning Authority iCXA

;

4

EU 4

O

PERATIONS

&

M

AINTENANCE

1 credit for providing digital operations and maintenance (O&M) manual

and energy management manual or an energy management section in

O&M manual which encourages effective communication.

1

EU 5

M

ETERING AND

M

ONITORING

3 credits for provided sub-metering that separately records and monitors

of electricity use by the following equipment installed by the Applicant

and serving the project space (at the minimum):

i.

HVAC&R systems (including supplementary air conditioning, if

any);

ii.

Lighting systems;

iii.

Small power (plug loads);

iv.

Lifts and escalators (if any);

v.

Hot water systems (if any);

vi.

Pools, Spa, whirlpools (if any);

vii.

Loads associated with server room (if any);

viii.

High electrical power equipment (>25kVA, if any).

1 credit for providing thermal energy metering and monitoring of the

chilled water consumption.

4

Section

Credit Requirement

Credit

6

W

ATER

U

SE

(WU)

6

WU 1

W

ATER

Q

UALITY

S

URVEY

1 credit for providing quality of potable water that meets the drinking

water quality standards at all points of use.

1

WU 2

A

NNUAL

W

ATER

U

SE

1 credit for demonstrating that the use of water efficient devices leads

to an estimated aggregate annual water saving of 30% when

compared with BEAM Plus baseline data herein.

2 credits for demonstrating an estimated annual water saving of 40%

when compared with BEAM Plus baseline data herein

Alternative:

1 credit for sensor type water taps were installed in the common area.

1 additional credit for Applicant can demonstrate that the water taps

mixer taps, and shower heads (where provided) in the host building

are Voluntary Water Efficiency Labelling Scheme (WELS) Grade 1

labelled or having the equivalent or lower flow rate.

2

WU 3

E

FFLUENT

D

ISCHARGE TO

F

OUL

S

EWERS

1 credit for provided water efficient technology in the flushing system.

Alternative:

1 credit for at least one water efficient flushing system is installed in

th

e host building .

1

WU 4

N

O

B

OTTLED

W

ATER

2 credits for replacing bottled water services with drinking water

fountains or equal;

2