Table of Contents Table of Contents
Previous Page  96 / 210 Next Page
Basic version Information
Show Menu
Previous Page 96 / 210 Next Page
Page Background

BEAM P

LUS

I

NTERIORS

C

OMMERCIAL

, R

ETAIL

A

ND

I

NSTITUTIONAL

W

ATER

U

SE

(WU)

WU 2 A

NNUAL

W

ATER

U

SE

Copyright © BEAM Society Limited. All rights reserved. Page 95

WU 2 A

NNUAL

W

ATER

U

SE

E

XCLUSION

None.

O

BJECTIVE

Reduce the consumption of fresh (potable) water through the

application of water saving devices that have proven performance and

reliability.

C

REDIT ATTAINABLE

2

C

REDIT REQUIREMENT

1 credit for demonstrating that the use of water efficient devices leads

to an estimated aggregate annual water saving of 30% when

compared with BEAM Plus baseline.

2 credits for demonstrating an estimated annual water saving of 40%

when compared with BEAM Plus baseline.

A

SSESSMENT

Criteria

Calculation shall be provided to determine the reduction of water

consumption in the project space compared with a similarly occupied

space whose water fittings and appliances conform to a baseline

performance. The calculation should take into account the number of

employees, and the number of operational days per annum. This

information must be supplied by the Applicant and may be stated in

the design brief or OPR.

Water use is based either on a ‘per operation’ basis or as the product

of flow rate and operation time. The default assumptions are given in

Appendix 9.3 .

Number of water devices installed and frequency of use

must be the same for both the baseline and project case.

Alternative:

If water taps and shower heads are not provided within th

e project space b

ut located in the shared common area (e.g. toilets/bathroom

shared with other tenants (or in retail premises located within

shopping centres etc) within the host building that is available to the

user of the project space:

1 credit can be achieved if, on same floor as the project

space, sensor type water taps are installed in the

shared/common area.

1 additional credit can be achieved where the Applicant

demonstrates that all water taps, mixer taps, and shower

heads (where installed) on that floor of the host building

comply with voluntary Water Efficiency Labelling Scheme

(WELS) [

1]

Grade 1 labelled or have an equivalent or lower

flow rate.

This alternative approach encourages conservation and raises

awareness, ultimately market forces motivating the building owner to

select or retrofit with water efficient fixtures.

Documentation

Credit(s) shall be achieved when the Applicant provides the

documentation stated below, to demonstrate compliance:

i.

Water saving calculation, example given in

Appendix 9.3 .

ii.

Drawings, architectural, floor layout plan;

1

Water Supplies Department. Voluntary Water Efficiency Labelling Scheme.

http://www.wsd.gov.hk/en/plumbing_and_engineering/wels/index.html