Page Background

BEAM P

LUS

I

NTERIORS

C

OMMERCIAL

, R

ETAIL

A

ND

I

NSTITUTIONAL

W

ATER

U

SE

(WU)

WU 3 E

FFLUENT

D

ISCHARGE TO

F

OUL

S

EWERS

Copyright © BEAM Society Limited. All rights reserved. Page 97

WU 3 E

FFLUENT

D

ISCHARGE TO

F

OUL

S

EWERS

E

XCLUSION

None.

O

BJECTIVE

Encourage reducing sewage volume discharge thereby reducing the

burden on municipal sewage, and water treatment facilities.

C

REDIT ATTAINABLE

1

C

REDIT REQUIREMENT

1 credit for the application of water efficient flushing water installation

technology;

A

SSESSMENT

Criteria

The Applicant demonstrates that the flushing systems installed within

th

e project space

are water efficient lowering sewerage volume.

Water efficient flushing systems include but not limited to:

i.

sensor type urinal;

ii.

waterless urinal;

iii.

flushing system certified by WELS Grade 1;

iv.

dual flush water closet;

Alternative

If the toilet areas are located in shared/common area of the host

building, one (1) credit is available where at least two (2) of the

prescribed water efficient flushing appliances above are installed

within the host building available to the occupants of the project

space.

The alternative approach encourages the occupier to examine the

host building before leasing, and motivates the building owner to

select or retrofit with water efficient flushing water installations.

If the occupants of the

project space

have access to toilet facilities in

both the common area and project space, only the sewerage

system(s) within the project space shall be counted. Where the host

building has shared common area toilet facilities fitted water efficient

appliances in (on the same floor) each Applicant on the same floor

achieve credit.

Documentation

Credit shall be achieved when the Applicant provides the

documentation stated below, to demonstrate compliance:

i.

calculation, sewerage volume;

ii.

manufacturer specifications/catalogue with flow rate data;

iii.

record photographs, for the flushing water installation;

Alternative (host building):

i.

Lease, or other document indicating occupant use of

shared/common area washroom facility;

ii.

Drawings, architectural, location plan for the facility

iii.

manufacturer’s information, technical data sheets with flow

rate data;

iv.

record photographs for the installation provided in host

building;