Table of Contents Table of Contents
Previous Page  29 / 210 Next Page
Basic version Information
Show Menu
Previous Page 29 / 210 Next Page
Page Background

BEAM P

LUS

I

NTERIORS

C

OMMERCIAL

, R

ETAIL

A

ND

I

NSTITUTIONAL

S

UMMARY OF

C

REDITS

Copyright © BEAM Society Limited. All rights reserved. Page 28

Section

Credit Requirement

Credit

4

M

ATERIALS

A

SPECTS

(MA)

26

MA P1

U

SE OF

N

ON

-

CFC B

ASED

R

EFRIGERANTS

Using no chlorofluorocarbon (CFC)-based refrigerants in HVAC&R or

other equipment which is installed by the Applicant.

Required

MA P2

M

INIMUM

W

ASTE

R

ECYCLING

F

ACILITIES

Provide storage facilities at prominent location for the collection and

recycling of paper, plastic and metal waste.

Required

MA P3

T

IMBER

U

SED

FOR

T

EMPORARY

W

ORKS

All timber used fo

r temporary works

shall originate from sustainable

sources or re-used from other sites.

Required

MA 1

W

ASTE

R

ECYCLING

F

ACILITIES

1 credit for providing storage and collection for any one (1) or

2 credits for providing storage and collection for any two (2) of the

following:

i.

Recycling of glass;

ii.

Recycling of used small electrical appliance;

iii.

Recycling of food waste;

2

MA 2

I

NTERIOR

C

OMPONENTS

R

EUSE

1 credit for reusing at least 30% of prior condition walls, glazing,

doors, ceiling and flooring.

2 credits for reusing at least 50% of prior condition walls, glazing,

doors, ceiling and flooring.

3 credits for reusing at least 70% of prior condition walls, glazing,

doors, ceiling and flooring.

The term

s Partitions

an

d Walls

are sometimes used interchangeably,

or combined together. However, in this Manual, each term has a

separate and specific meaning.

3

MA 3

F

URNITURE AND

P

ARTITIONS

1 credit for at least 30% of the total furniture and partitions were

reused from salvaged furniture and partitions.

2 credits for at least 50% of the total furniture and partitions were

reused from salvaged furniture and partitions.

3 credits for at least 70% of the total furniture and partitions were

reused from salvaged furniture and partitions.

The term

s Partitions

an

d Walls

are sometimes used interchangeably,

or combined together. In this Manual each has a separate and

specific meaning.

3

MA 4

M

ODULAR

D

ESIGN

M

ATERIALS

1 credit for modular elements which contributed at least 50% of the

newly installed elements in the project.

1

MA 5

D

ESIGNED FOR

D

ISASSEMBLY

1 credit for easy to disassemble elements which contributed at least

50% of the newly installed elements in the project.

1