Table of Contents Table of Contents
Previous Page  34-35 / 188 Next Page
Basic version Information
Show Menu
Previous Page 34-35 / 188 Next Page
Page Background

BEAM P

LUS FOR

E

XISTING

B

UILDINGS

F

RAMEWORK

V

ERSION

1.2

Copyright © 2012 BEAM Society Limited. All rights reserved.

Page 20

1 credit for demonstrating highly efficient irrigation technology and/or the use of

harvested rainwater and/or recycled grey water to reduce fresh water

consumption for irrigation by 50% or more in comparison with conventional

irrigation of water intensive planting.

building footprint.

W

U

4 W

ATER

R

ECYCLING

1 credit for harvesting rainwater and/or recycling greywater that leads to a

reduction of 5% or more in the consumption of fresh water.

None.

1

1 BONUS credit where harvesting and/or recycling leads to a reduction of 10% or

more in the consumption of fresh water.

1B

W

U

5 W

ATER

AUDIT

1 BONUS credit for undertaking a water audit and maintaining a water use

inventory.

None.

1B

W

U

6 E

FFLUENT

D

ISCHARGE TO

F

OUL

S

EWERS

1 credit for demonstrating a reduction in annual sewage volumes by 20% or

more, or reduction in sewage concentration by a 30% or more.

None.

1

6

I

NDOOR

E

NVIRONMENTAL

Q

UALITY

(I

EQ

)

30+3B

I

EQ

P1 M

INIMUM

V

ENTILATION

P

ERFORMANCE

Demonstrate that the project is in compliance with the minimum requirements of

ASHRAE 62.1-2007 in respect of Outdoor Air Quality and

Minimum Ventilation

Rate.

Residential and similar

buildings without central

air conditioning.

Required

I

EQ

1 S

ECURITY

1 credit for scoring at least 75% of the applicable security measures and facilities

for the building.

None.

1

I

EQ

2 P

LUMBING AND

D

RAINAGE

1 credit where system design, operation and maintenance is such as to reduce

the potential for transmission of harmful bacteria viruses, and odours.

None.

1

I

EQ

3 B

IOLOGICAL

C

ONTAMINATION

1 credit for complying with the recommendations given in the Code of Practice -

Prevention of Legionnaires Disease, in respect of air-conditioning and ventilation

systems, and water systems.

Residential buildings.

1

I

EQ

4 W

ASTE

D

ISPOSAL

F

ACILITIES

1 credit for the provision of a de-odourising system in all refuse collection rooms. None.

1

I

EQ

5 I

NTEGRATED

P

EST

M

ANAGMENT

1 credit for implementing an integrated programme for pest management.

None.

1

I

EQ

6 C

ONSTRUCTION

IAQ

M

ANAGEMENT

1 credit for availability and effective implementation of a Construction IAQ

Management.

Residential and similar

buildings.

1

I

EQ

7 O

UTDOOR

S

OURCES OF

A

IR

P

OLLUTION

1 credit for demonstrating compliance with appropriate criteria for Carbon

monoxide, Nitrogen dioxide and Ozone.

Buildings that are

designed for natural

ventilation or using de-

centralised a/c system.

1