8.8 P

ASSIVE

D

ESIGN

A

SSESSMENT

M

ETHODOLOGY

Copyright © 2012 BEAM Society Limited. All rights reserved.

A - 30

a

b

c

Habitable area

Pass – windows lie in different

halves

Fail – windows lie in same half

Assessment box

Half way line

The total openable window size (i.e. physical opening not aerodynamic free

area) in each habitable area shall be double of that of the statutory

requirement (i.e.1/8 of openable window area to usable floor area);

When considering a single room the openable window size located at each

wall shall be at least 1/16 of the usable floor area;

To ensure cross ventilation can affect the majority of the habitable space, it

is required to have the windows a reasonable distance apart. To assess

this, draw the smallest box possible that covers the habitable area and

divide into equal halves through the longest side. The windows shall lie in

different halves of the habitable area. (Figure 8.8.1.4-2)

Figure 8.8.1.4-2: Allowable locations of windows in a zone