Page 148

6

IEQ

6.2

H

YGIENE

I

EQ

4 W

ASTE

D

ISPOSAL

F

ACILITIES

E

XCLUSIONS

None.

O

BJECTIVE

Ensure that the design, installation and facilities waste disposal and

recycling are such as to reduce the risk of odours entering occupied

areas or public areas.

C

REDITS ATTAINABLE

1

P

REREQUISITES

Compliance with the Building (Refuse Storage Chambers and Material

Recovery Chambers and Refuse Chutes) Regulations.

C

REDIT REQUIREMENT

1 credit for the provision of a de-odourising system in all refuse collection

rooms and chambers

.

A

SSESSMENT

The Client shall submit details of the de-odourising systems, noise

control abatement system and fire protection provisions. The system

shall comply with those recommendations contained in PNAP No. APP-

35 [1] in respect of refuse storage and recovery chambers appropriate to

the given circumstances.

The provision of a purpose-designed automated/mechanical system for

waste disposal is deemed to meet the requirements.

B

ACKGROUND

Where refuse contains large amounts of food and other organic waste

there are potential odours and health problems if refuse is not well

contained from the points of disposal by users to the place of final

collection. Automatic systems are available to isolate refuse from users.

R

EFUSE

C

HAMBERS

Where a centralised ventilation system is adopted, a single air purifier

may be installed before final discharge into the atmosphere. Alternatively

where there is no particular odour problem a mechanical fan coupled

with a particulate filter at each RS&MRR/MRC may be considered. The

main exhaust outlet for a centralised ventilation system should be

located at upper roof level away from other buildings; however in the

case where the building is surrounded by taller buildings the discharge

may be located at the main RS&MRC.

The noise level of the system should conform with the Technical

Memorandum [2] published under the Noise Control Ordinance (Cap

400). Fire dampers should be provided if the system has exhaust grilles

and ducting at each floor.

Air purifying devices such as ‘Chemical Air Scrubber’, ‘Bio-oxygen

Generator’, ‘Photo-oxidation Generator’ or other appropriate devices

should be provided within a RS&MRC.

1

Buildings Department. Practice Note for Authorized Persons, Registered Structural Engineers and Registered

Geotechnical Engineers, PNAP No. APP-35 Refuse Storage and Collection Building (Refuse Storage and Material

Recovery Chambers and Refuse Chutes) Regulations

. http://www.bd.gov.hk/english/documents/pnap/APP/APP035.pdf

2

Environmental Protection Department. Technical Memorandum for the Assessment of Noise from Places other than

Domestic Premises, Public Places or Construction Sites.

http://www.epd.gov.hk/epd/english/environmentinhk/noise/guide_ref/tm_nonpp.html