Table of Contents Table of Contents
Previous Page  163 / 248 Next Page
Basic version Information
Show Menu
Previous Page 163 / 248 Next Page
Page Background

BEAM P

LUS FOR

N

EW

B

UILDINGS

I

NDOOR

E

NVIRONMENTAL

Q

UALITY

(I

EQ

)

V

ERSION

1.2

I

EQ

1 S

ECURITY

Copyright © 2012 BEAM Society Limited. All rights reserved.

Page 142

6

IEQ

6.1

S

ECURITY

I

EQ

1 S

ECURITY

E

XCLUSIONS

None.

O

BJECTIVE

Engender a feeling of well-being amongst building users.

C

REDITS ATTAINABLE

1

P

REREQUISITES

Burglar alarm systems shall comply with the Noise Control Ordinance.

C

REDIT REQUIREMENT

1 credit for scoring at least 75% of the applicable security measures and

facilities for the building.

A

SSESSMENT

The Client shall submit a report prepared by a suitably qualified person

which includes a completed checklist of the security measures and

facilities provided, justification for each checked item, details of the

physical security systems provided, and a detailed security manual

explaining how the physical provisions (hardware) integrate with the

management system (software) for the building.

Where 75% compliance of applicable items is demonstrated, the credit

shall be awarded.

Alternatively, the Client may provide detailed rationale and arguments to

demonstrate that security systems are integrated and an enhanced

standard of security can be provided.

A

SSESSMENT

G

RID

Site perimeter controls:

Pt

Surveillance:

Pt

Building Security:

Pt

Site/Building

Layout

Pt

Site is fenced, gate(s)

attended during active

hours, intercom and

camera surveillance during

silent hours.

2

or

Lighting of site:

Overall illumination of

the site is between 50

and 200 lux.

2

or

Entry from adjacent

building(s):

Access is prevented by a

separating distance of 6m.

2

or

Pathways are short,

wide and straight

1

Restricted areas of the site

are fenced with a locked

gate.

1 Site is illuminated by

street and building

exterior lighting.

1 Access from adjacent

building is inhibited by

barriers.

1 Footpaths are well

lit, convex steel

mirrors to forestall

concealment.

1

Vehicle Access Control:

Parking is indoor and with

attended control station.

2

or

Monitoring of site:

Colour monitoring of

building entrances and

perimeter.

2

or

Security guards can verify by

CCTV monitor and card

reader.

2

or

Amenity/play areas

overlooked from the

building.

1

Parking for visitors and

building users are

separated with guard

patrol.

1 B&W monitoring of

building entrances and

perimeter.

1 All people and traffic from

parking must pass security

control or parking control

station.

1 Elevators are

monitored by

CCTV.

1

Security of stored vehicles:

Company vehicles in

indoor parking or fenced

compound with CCTV

monitoring in silent hours.

2

or

Guard patrol:

Frequent patrol of

building and fence

perimeter.

2

or

Doors and windows at grade:

Secured with heavy duty

hardware, security glazing

and deadlocks.

2

or

Staircases are wide,

open and well lit.

1

Company vehicles in

separate well lit area.

1 Single guard patrol

during silent hours.

1 Secured with high grade

hardware.

1 Meters are located

in common areas

1

Optional (by Client)

2

or

Planting: clear of

building pathways and

parking.

2

or

Alarmed for opening and

breakage to central control

and perimeter is monitored

with CCTV.

2

or

Optional (by Client) 2

or

Optional (by Client)

1 Planting 6m clear of

building.

1 Alarmed locally for opening

and breakage.

1 Optional (by Client) 1

Total Applicable Points:

Points Achieved:

Percentage Achieved: