BJECTIVES

Encourage the wider application of renewable energy sources in

buildings.

C

REDITS ATTAINABLE

5

P

REREQUISITES

None.

C

REDIT REQUIREMENT

1 to 5 credits where 0.5% to 2.5% or more of building energy

consumption is obtained from renewable energy sources respectively.

Alternatively,

1 to 5 credits where the minimum percentage of 20% to 100% of the

building footprint is being covered/used by PV panels respectively and/or

other renewable power facility generation with equivalent renewable

power output.

A

SSESSMENT

The Client shall submit a report providing details of the installations, and

calculations showing the estimated energy use provided from renewable

energy sources.

In the case of systems that generate electricity from renewable sources

(e.g. photovoltaic panels), the estimated amount of electricity that will be

generated by the system for use by equipment in the building, either

instantaneously or from an associated storage system.

In the case of using systems that produce services direct from renewable

sources, which will otherwise require the use of fuel or electricity to

produce those services (e.g. hot water supply from solar panels or chilled

water supply from absorption chillers powered by solar heat), the

equivalent amount of electricity use that will be avoided.

The calculation shall take due account of the diurnal and seasonal

variations in the external environmental conditions (e.g. solar intensity

and wind speed and direction) and in the demand for the electricity

and/or services generated by the systems. Any energy use and losses

by the systems shall be discounted from their output. The total energy

consumption shall be referenced to the design value calculated in the

Credit E

U

1 Reduction of CO

2

Emission or other building energy

estimation certified by a qualified professional person when EU 1 –

Option 2 Alternative Route: Passive Design is adopted. The tenant’s

electrical loads, which are not controlled or influenced by the applicant,

shall be excluded from the calculation.

Alternatively, the credits may be awarded where the Client demonstrates

that percentage of the building footprint is being covered/used by PV

panels and/or other renewable power facility generation equivalent

renewable power output. The number of credits awarded will be

determined with reference to the percentage achieved.

B

ACKGROUND

If energy consumption continues to increase at existing levels, projected

carbon dioxide emissions generated for the year 2010 are expected to

grow by 39% from the 2000 level. The effective use of renewable energy

resources will help to reduce Hong Kong's reliance on fossil fuels and

also to reduce greenhouse gas emissions arising from the use of fossil

fuels. EMSD’s information pamphlet [ 1 ] explains the meaning of

1

Electrical and Mechanical Services Department

. http://www.emsd.gov.hk/emsd/e_download/sgi/re_pamphlet.pdf