Equation 1
– Determining the total quantity of renewable materials /
recycled materials / sustainable timber.
Qualified
Content (%)
=
∑ (Rapidly Renewable Materials + Recycled
Materials + Sustainable Timber) (m
2
)
x 100%
∑ Newly Installed Wall and Door Materials (m
2
)
Equation 2
– Determining the total quantity of regionally
manufactured materials.
Total
Regionally
Manufactured
Materials (%)
=
∑ Regionally Manufactured Materials (m
2
)
x 100%
∑ Newly Installed Wall and Door Materials (m
2
)
Equation 3
– Determining the total quantity of environmentally
manufactured materials.
Total
Environmentally
Manufactured
Materials (%)
=
∑ Environmentally Manufactured Materials (m
2
)
x 100%
∑ Newly Installed Wall and Door Materials (m
2
)
Note: Only the newly installed
wallsand doors shall be assessed.
Existing party walls (shared with adjacent unit), and structural core
walls are excluded from this assessment.