IEQ 11 A

COUSTICS

Copyright © BEAM Society Limited. All rights reserved. Page 119

IEQ 11 A

COUSTICS

E

XCLUSION

None.

O

BJECTIVE

Encourage comfortable acoustic environment for occupants.

C

REDIT ATTAINABLE

3

C

REDIT REQUIREMENT

1 credit for demonstrating background noise levels are within the

prescribed criteria to ensure the well-being of the occupant.

1 credit for demonstrating that the reverberation time in applicable

areas meets the prescribed criteria for given types of premises to

ensure the speech clarity.

1 credit for demonstrating airborne noise isolation between rooms,

spaces and premises meets the prescribed criteria to ensure the

speech privacy.

A

SSESSMENT

Criteria

A. Internal Noise level:

i.

Classrooms - NC 35

ii.

Conference rooms - NC 35

iii.

Offices - NC 40

iv.

Retail shops and restaurants - NC 45

v.

Hotel rooms and serviced apartments - NC 35

vi.

Function, multi-function, and activity rooms - NC 45

Note: If on-site measurement is adopted, the measurement should be

based on an equivalent continuous sound level of 5 minutes [Leq

(5mins)] with the HVAC&R system operating under normal condition.

B. Reverberation time:

The average reverberation time for mid frequencies (500Hz, 1kHz and

2kHz), shall not exceed:

i.

Classrooms - 0.6s

ii.

Conference rooms - 0.6s

iii.

Offices - 0.6s

iv.

Retail shops, and restaurants - 1s

v.

Hotel rooms and service apartments - 0.4 to 0.6s

vi.

Function, multi-function and Activity rooms - 0.6s

C. Air-borne noise isolation:

i.

Between 2 classrooms - STC 37

ii.

Between 2 conference rooms and office/conference - STC 48

iii.

Between 2 offices – STC 48

iv.

Between 2 retail shops - STC 48

v.

Between 2 hotel rooms or serviced apartments - STC 52

vi.

Between 2 function or activity rooms - STC 52