BEAM P

LUS

I

NTERIORS

C

OMMERCIAL

, R

ETAIL

A

ND

I

NSTITUTIONAL

I

NDOOR

E

NVIRONMENTAL

Q

UALITY

(IEQ)

IEQ 10 V

IEWS TO

O

UTSIDE

Copyright © BEAM Society Limited. All rights reserved. Page 117

IEQ 10 V

IEWS TO

O

UTSIDE

E

XCLUSION

None.

O

BJECTIVE

Provide occupants in normally occupied spaces with a connection to

the outdoors.

C

REDIT ATTAINABLE

2

C

REDIT REQUIREMENT

1 credit for at least 60% of all workstations or seating have a direct

line of sight to external vision glazing or naturally lit internal courtyard

or atrium.

2 credits for at least 80% of all workstations or seating have a direct

line of sight to external vision glazing or naturally lit internal courtyard

or atrium.

A

SSESSMENT

Criteria

The assessment is focused toward workplaces such as offices,

schools, and retail etc., where connection to the outside is regarded

as important for comfort and productivity. Interior spaces that need

not be considered include public corridors, lift lobbies, conference

rooms, storage areas, printing rooms, plant rooms, and server rooms.

On the plan view sight lines shall be drawn from each workstation or

seating location to the exterior vision glazing. In section view, direct

sight lines shall be drawn for each workstation or seating from a point

1.2m above the floor (Fig. 1).

The project workstations or seating shall be within 8m of the nearest

vision glazing and have a direct line of sight at seated eye level of

1.2m of the vision glazing. The view shall be either through an

external window providing a view of landscape, streetscape or

buildings, or atrium (atrium shall mean a naturally lit atrium, or internal

courtyard, not less than eight (8) metres wide).

The view can be an internal view across a space providing the

Applicant can provide photos that the interior layout shall be such that

views will not be impaired once all

walls , partitions a

nd furniture has

been installed.

IMPORTANT NOTE: All submissions comprising several type of data,

for example, table, layout drawings, elevations, photographs and

other data, shall be clearly labelled and cross-referenced.

Documentation

Credit(s) shall be achieved when the Applicant provides the

documentation stated below, to demonstrate criteria compliance:

i.

summary table with location, distances;

ii.

drawings, floor layout plan, elevations

iii.

workstations or seating clearly indicated;

iv.

record photographs;

B

ACKGROUND

A very important psycho-emotional factor for building occupants who

remain indoors for long periods is the visual contact with the exterior.

The ability to focus the eyes on a distant view provides for relaxation.