V

ERSION

1.2

F

RAMEWORK

Copyright © 2012 BEAM Society Limited. All rights reserved.

Page 25

I

EQ

13 T

HERMAL

C

OMFORT IN

A

IR

-

CONDITIONED

P

REMISES

1 credit for sustaining the air temperature at the design value within ±1.5

C when

the air side system is operating at steady state under normal occupied periods.

Premises where air-

conditioning is provided

by window units or split

units.

1

1 credit where room air diffusers satisfy the Air Diffusion Performance Index.

1

I

EQ

14 T

HERMAL

C

OMFORT IN

N

ATURALLY

V

ENTILATED

P

REMISES

1 credit for demonstrating indoor operative temperatures in occupied/habitable

rooms meet the 80% acceptability limits.

Buildings that are not

designed to utilise

natural ventilation.

1

Alternatively,

1 credit for demonstrating the predicted Mean Vote (PMV) in occupied/habitable

rooms is between –1 and +1.

Alternatively,

1 credit for demonstrating that, the thermal performance, and the internal wind

speeds, of the occupied/habitable rooms fall within the 80% acceptability range

for the tropical climate conditions of Hong Kong.

1

1 credit for sustaining the air temperature at the design value within ±1.5

when

the air-conditioning unit is operating at steady state under normal occupied

periods.

I

EQ

15 N

ATURAL

L

IGHTING

1 credit where at least 80% of the floor area in all normally occupied spaces is

adequately lit with an average daylight factor of 1%.

None.

1

2 credits where at least 95% of the floor area in all normally occupied spaces is

adequately lit with an average daylight factor of 1%.

1

I

EQ

16

I NTERIOR L IGHTING IN N ORMALLY O CCUPIED A REAS

1 credit where the prescribed lighting performance in each type of premises in

respect of illuminance and lighting quality is achieved.

I

t is required to fulfill (i) prescribed lighting performance in respect of maintained

illuminance and illumance variation; and (ii) the limiting unified glare rating is

achieved and light sources have an appropriate colour rendering index.

Residential buildings,

hotels and apartment

buildings.

1

1 BONUS credit for providing automatic control of artificial lighting such as

daylight sensors at perimeter zone and/or occupancy sensor.

1B

I

EQ

17

I NTERIOR L IGHTING IN A REAS NOT N ORMALLY O CCUPIED 1

credit where the prescribed lighting performance in each type of common or

service space in respect of light output and lighting quality is achieved.

None.

1

I

EQ

18 R

OOM

A

COUSTICS

1 credit for demonstrating that intruding noise levels are within the prescribed

criteria and the mid-frequency reverberation time in applicable rooms meets the

prescribed criteria for give types of premises.

Buildings/premises

where speech

intelligibility is not

important, and rooms of

1