Table of Contents Table of Contents
Previous Page  42-43 / 248 Next Page
Basic version Information
Show Menu
Previous Page 42-43 / 248 Next Page
Page Background

BEAM P

LUS FOR

N

EW

B

UILDINGS

V

ERSION

1.2

F

RAMEWORK

Copyright © 2012 BEAM Society Limited. All rights reserved.

Page 24

I

EQ

5

C ONSTRUCTION IAQ M ANAGEMENT

1 credit for implementing a Construction IAQ Management Plan.

Residential and similar

buildings not provided

with central air-

conditioning and

ventilation systems.

1

1 credit for undertaking a building ‘flush out’ or ‘bake out’; and replacement of all

filters prior to occupancy.

1

I

EQ

6 O

UTDOOR

S

OURCES OF

A

IR

P

OLLUTION

1 credit for demonstrating compliance with appropriate criteria for carbon

monoxide, nitrogen dioxide and ozone.

Buildings that are

designed for natural

ventilation or using de-

centralised A/C system.

1

1 credit for demonstrating compliance with the appropriate criteria for RSP.

1

I

EQ

7 I

NDOOR

S

OURCES OF

A

IR

P

OLLUTION

1 credit for demonstrating compliance with the appropriate criteria for volatile

organic compounds.

Items a) & b) are

excluded for buildings

that are designed for

natural ventilation or

using de-centralised

A/C system and without

interior decoration.

1

1 credit for demonstrating compliance with the appropriate criteria for

formaldehyde.

1

1 credit for demonstrating compliance with the appropriate criteria for radon.

1

I

EQ

8 IAQ

IN

C

AR

P

ARKS

1 credit for demonstrating compliance with the design requirements specified in

ProPECC PN 2/96.

Buildings with no car

park.

1

I

EQ

9 I

NCREASED

V

ENTILATION

1 credit for demonstrating an outdoor ventilation rate that exceeds ASHRAE

62.1:2007 requirements by at least 30%

Residential and

similar buildings

without central air

conditioning.

1

I

EQ

10

B ACKGROUND V ENTILATION 1

credit where it can be demonstrated that adequate ventilation can be achieved

by natural means.

Buildings not designed

to utilise natural

ventilation.

1

I

EQ

11

L OCALISED V ENTILATION

1 credit for the provision of an adequate ventilation system for rooms/areas

where significant indoor pollution sources are generated.

2

nd

credit not applicable

to residential and

similar buildings.

1

1 credit for the provision of a general exhaust system for future tenants.

1

I

EQ

12

V ENTILATION IN C OMMON A REAS

1 credit for demonstrating that all enclosed common areas in a building are

p

rovided with adequate ventilation.

Spaces covered under

the section on

Localised Ventilation.

1

1 BONUS credit where the provision for ventilation is by natural means.

1B