BJECTIVE

Reduce the release of chlorofluorocarbons (CFCs) and

hydrochlorofluorocarbons (HCFCs) into the atmosphere.

C

REDITS ATTAINABLE

2

P

REREQUISITES

Compliance with the Ozone Layer Protection Ordinance Chapter 403.

C

REDIT REQUIREMENT

a) Refrigerants

1 credit for the use of refrigerants with a value less than or equal to the

threshold of the combined contribution to ozone depletion and global

warming potentials using the specified equation.

b) Ozone depleting materials

1 credit for the use of products in the building fabric and services that

avoid using ozone depleting substances in their manufacture,

composition or use.

A

SSESSMENT

a) Refrigerants

The air-conditioning and refrigeration equipments shall fulfill the following

equation which determines a maximum threshold for the combined

contributions to ozone depletion and global warming potentials:

LCGWP + LCODP

10

5

≤ 775

LCGWP = [GWPr

(Lr

Life + Mr)

Rc] / Life

LCODP = [ODPr

(Lr

Life + Mr)

Rc] / Life

LCGWP = Lifecycle Global Warming Potential (kg CO

2

/kw -Yr)

LCODP = Lifecycle Ozone Depletion Potential (kg CFC 11/kw-Yr)

GWPr = Global Warming Potential of Refrigerant (0 to 12,000 kg CO

2

/kg r )

ODPr = Ozone Depletion Potential of Refrigerant (0 to 0.2 kg CFC 11

/kg r )

Lr = Refrigerant Leakage Rate (0.5% to 2.0%; default of 2% unless

otherwise demonstrated)

Mr = End-of-life Refrigerant Loss (2% to 10%; default of 10% unless

otherwise demonstrated)

Rc = Refrigerant Charge (0.2 to 2.3 kg of refrigerant per kW of gross

ARI rated cooling capacity)

Life = Equipment Life (10 years; default based on equipment type,

unless otherwise demonstrated)

For systems with different types of equipment, a weighted average of all

air-conditioning and refrigeration equipments shall be calculated using

the following equation:

[ ∑ (

LCGWP + LCODP

10

5

)

Qunit ] / Qtotal ≤ 775

Qunit = Gross ARI rated cooling capacity of an individual air-

conditioning or refrigeration unit (kW)

Qtotal = Total gross ARI rate cooling capacity of all air-conditioning or