Table of Contents Table of Contents
Previous Page  115 / 188 Next Page
Basic version Information
Show Menu
Previous Page 115 / 188 Next Page
Page Background

BEAM P

LUS FOR

E

XISTING

B

UILDINGS

W

ATER

U

SE

(W

U

)

V

ERSION

1.2

W

U

2 M

ONITORING AND

C

ONTROL

Copyright © 2012 BEAM Society Limited. All rights reserved.

Page 97

5

W

ATER

U

SE

5.1

W

ATER

C

ONSERVATION

W

U

2 M

ONITORING AND

C

ONTROL

E

XCLUSIONS

None.

O

BJECTIVE

Reduce wastage of fresh water and allow for auditing of water use.

C

REDITS ATTAINABLE

1

P

REREQUISITES

Compliance with Waterworks Regulation Chapter 102A Regulation 32.

C

REDIT REQUIREMENT

1 credit for installation of devices to monitor water leakage within the

fresh water distribution system.

A

SSESSMENT

The Client shall submit a report detailing any system for monitoring water

leaks within internal plumbing installations.

The assessment will seek to establish if mechanisms are in place that

effectively limit wastage of water by the application of water saving

devices. The provision of devices for monitoring consumption for each of

the major water using sectors shall be identified.

Various approaches are available and BEAM is not intended to be

prescriptive as to which should be used.

B

ACKGROUND

The provision of automatic shut-off devices, particularly in public use

areas, can save significant amounts of water. Examples of automatic

shut-off devices are spring-loaded taps, electronic proximity sensors,

etc., but excluding timed shut-off devices.

Generally in Hong Kong buildings there is very limited provision for

monitoring water use other than the meters required for utility billing

purposes. The provision of measurement devices for major water uses

can assist facility managers to audit water use and can encourage the

introduction of water saving measures.