OISE

I

SOLATION

Copyright © 2012 BEAM Society Limited. All rights reserved.

Page 181

6

IEQ

6.7

A

COUSTICS AND

N

OISE

I

EQ

19 N

OISE

I

SOLATION

E

XCLUSIONS

Buildings/premises which are inherently noisy and unaffected by noise

from adjacent premises/spaces.

O

BJECTIVE

Improve the noise isolation of normally occupied premises/rooms to

reduce impact of unwanted noise.

C

REDITS ATTAINABLE

1 + 1 BONUS

P

REREQUISITES

None.

C

REDIT REQUIREMENT

1 credit for demonstrating airborne and impact noise isolation between

rooms, spaces and premises meets the prescribed criteria.

For residential developments only,

1 BONUS credit for demonstrating impact noise isolation between floors

meets the prescribed criteria.

Based on the nature of the building, relaxation should be allowed in

considering the acceptance of this credit. The applicant should provide

full submission of the design and calculation to justify the relaxation.

A

SSESSMENT

As there are number of ways to quantify or classify noise isolation

(insulation) in buildings, the exact performance criteria used to define

both airborne noise isolation and impact noise isolation shall be stated by

the Client. However, for the purposes of assessment account should be

taken of the criteria given below. Where alternative criteria is used the

Client shall provide evidence as to the suitability of the alternative, e.g.

by making reference to authoritative guidance. Likewise, where criteria

appropriate to the type and use of premises/spaces is not stated herein,

the Client shall provide evidence as to the suitability of the criteria

adopted.

Compliance shall be demonstrated by measurement or by detailed

calculations, or both, depending on the Client’s preference.

Measurements shall follow the protocols given in the referenced

standards. Calculations should be done with reference to appropriate

standards.

The Client shall submit details in the form of a report prepared by a

suitably qualified person providing a schedule of the premises and

spaces in the building, the noise isolation criteria adopted, relevant

structural details as they impact on noise isolation, the rooms/premises

subject to field tests or for which detailed calculations have been made,

underlying assumptions, and the results of tests or calculations

demonstrating compliance with the criteria (expressed in parameters that

are consistent with the test and/or calculation methods).

Where it can be demonstrated that airborne noise isolation, as measured

or calculated for the most susceptible spaces/rooms/premises, meets

appropriate performance criteria the credit shall be awarded.

For residential development, where it can demonstrate that impact noise

isolation (insulation) meet appropriate performance criteria in the most

susceptible spaces/ rooms/premises, the BONUS credit shall be